MV Kalliopi N
UnderwayDeparture AuthorisedExecutive vessel operating picture. Drill down only where an exception exists.
Current / next service
Georgetown → Port Kaituma
Departed Yesterday 22:10 · ETA Tomorrow 04:40
Location
North West coastal transit
Position updated 51 sec ago
Operating restriction
None
Next required inspection
Six-month safety systems inspection, 12 September
Open critical issues
0
1 other open action
Safety & compliance
Recorded requirements and whether they have been satisfied
Departure authorised
- ✓Required operational checks completed
- ✓Required crew confirmed
- ✕Required inspections current
- ✓Manifest reconciled
- ✓No blocking restrictions recorded
- Authorised by
- R. Persaud, Harbour Master
- Time
- 09:57
Inspections & certification
| Requirement | Last completed | Next due / expiry | Status |
|---|---|---|---|
| Pre-departure inspection | 17 Aug 09:41 | Current voyage | Current |
| Six-month safety systems inspectionNo findings recorded at last inspection | 12 Mar | 12 Sep | Current |
| Life-saving equipment inspection | 11 Jun | 11 Dec | Current |
| Vessel certificate | — | 4 Dec | Current |
| Passenger vessel safety certificate | 18 Apr | 18 Apr 2027 | Current |
| Annual hull survey | 04 Feb | 04 Feb 2027 | Current |
Outstanding compliance issues
- Fire systems inspection overdue, inspection not yet recordedREQ-FS-07
Crew and safety equipment: compliant.
Maintenance & condition
Condition by vessel domain, from maintenance reports, inspections, defect reports and completed repairs
| Domain | Status | Open | Latest significant issue |
|---|---|---|---|
| Propulsion | Normal | 0 | — |
| Steering | Normal | 0 | — |
| Electrical | Normal | 0 | — |
| Hull & Structure | Normal | 0 | — |
| Fire & Safety Systems | Normal | 0 | — |
| Navigation & Communications | Normal | 0 | — |
| Pumps & Bilge | Normal | 0 | — |
| Deck & Loading Equipment | Normal | 0 | — |
| Auxiliary Systems | Warning | 1 | Coolant temperature above threshold, intake pressure declining |
Maintenance records
Auxiliary Systems
- MR-0249 Starboard sea water cooling, Coolant temperature above threshold, intake pressure decliningMonitoring
Sea strainer suspected partially fouled. Monitoring in place with hourly reporting; inspection at first safe opportunity.
Source: Defect report (DEF-1184)17 AugResponsible: Marine Engineering
Open issues & actions
Significant current matters for this vessel
- Risk RSK-011: Repeated crew procedure non-complianceEscalated
3 recorded omissions in 30 days across two vessels.
Open RSK-011 → - Risk RSK-016: Wet-weather slips on passenger stairsUnder review
3 wet-deck slips recorded this quarter, all on stair access in rain.
Open RSK-016 → - Action ACT-0092: MV Kalliopi N, cooling system monitoring regimeIn progress
Maintain reduced power, report coolant temperature every 30 minutes until arrival.
Open ACT-0092 →