MV Kanawan
UnderwayDeparture AuthorisedExecutive vessel operating picture. Drill down only where an exception exists.
Current / next service
Parika → Supenaam
Departed 09:58 · ETA 11:17
Location
Essequibo River, underway
Position updated 18 sec ago
Operating restriction
None
Next required inspection
Six-month safety systems inspection, 12 September
Open critical issues
0
1 other open action
Safety & compliance
Recorded requirements and whether they have been satisfied
Departure authorised
- ✓Required operational checks completed
- ✓Required crew confirmed
- ✕Required inspections current
- ✓Manifest reconciled
- ✓No blocking restrictions recorded
- Authorised by
- R. Persaud, Harbour Master
- Time
- 09:57
Inspections & certification
| Requirement | Last completed | Next due / expiry | Status |
|---|---|---|---|
| Pre-departure inspection | 17 Aug 09:41 | Current voyage | Current |
| Six-month safety systems inspectionNo findings recorded at last inspection | 12 Mar | 12 Sep | Current |
| Life-saving equipment inspection | 11 Jun | 11 Dec | Current |
| Vessel certificate | — | 4 Dec | Current |
| Passenger vessel safety certificate | 18 Apr | 18 Apr 2027 | Current |
| Annual hull survey | 04 Feb | 04 Feb 2027 | Current |
Outstanding compliance issues
- Fire systems inspection overdue, inspection not yet recordedREQ-FS-07
- Crew fitness declaration review outstanding before next assignmentACT-0090
Crew & equipment exceptions
- ⚠ Fitness declaration1 exception, review requiredDeck rating fitness declaration expires 21 Aug, review before next assignment (ACT-0090)
Maintenance & condition
Condition by vessel domain, from maintenance reports, inspections, defect reports and completed repairs
| Domain | Status | Open | Latest significant issue |
|---|---|---|---|
| Propulsion | Normal | 0 | — |
| Steering | Normal | 0 | — |
| Electrical | Normal | 0 | — |
| Hull & Structure | Normal | 0 | — |
| Fire & Safety Systems | Warning | 1 | Low output pressure |
| Navigation & Communications | Normal | 0 | — |
| Pumps & Bilge | Normal | 0 | — |
| Deck & Loading Equipment | Normal | 0 | — |
| Auxiliary Systems | Normal | 0 | — |
Maintenance records
Fire & Safety Systems
- MR-0248 Fire Pump #1, Low output pressureRepair scheduled
Output pressure below required threshold during weekly test. Vessel operation not affected; secondary pump verified serviceable. Repair scheduled at next layover.
Source: Defect report (DEF-1179)15 AugResponsible: Marine Engineering
Open issues & actions
Significant current matters for this vessel
- Risk RSK-011: Repeated crew procedure non-complianceEscalated
3 recorded omissions in 30 days across two vessels.
Open RSK-011 → - Risk RSK-016: Wet-weather slips on passenger stairsUnder review
3 wet-deck slips recorded this quarter, all on stair access in rain.
Open RSK-016 → - Action ACT-0090: MV Kanawan, crew fitness compliance reviewAwaiting verification
Confirm replacement certification and submit evidence before next roster.
Open ACT-0090 → - Incident INC-0448: Fire detection panel zone 4 indicator lamp dimMonitoring
17 Aug, 09:41 · Safety equipment failure
Open INC-0448 →