Transport and Harbours Department logoTransport & Harbours DepartmentIntegrated Operations & Safety Command Centre

MV Sabanto

UnderwayRestricted

Executive vessel operating picture. Drill down only where an exception exists.

← All vessels
Restriction Maximum 55% port engine load. Fuel filter differential pressure (DEF-1183). Until Engineering inspection and pressure test completed. RES-0042
Current / next service
Parika → Bartica
Departed 10:05 · ETA 13:22
Location
Essequibo River, underway
Position updated 2 mins ago
Operating restriction
Maximum 55% port engine load
Engine load restricted to 60% pending cooling system inspection
Next required inspection
Six-month safety systems inspection, 12 September
Open critical issues
0

Safety & compliance

Recorded requirements and whether they have been satisfied

Departure authorised
Departure authorised

Engine load restricted to 60% pending cooling system inspection

  • Required operational checks completed34 / 34 checks, 09:52
  • Required crew confirmed12 / 12 carried
  • Required inspections currentCooling system inspection instructed on arrival (ACT-0092)
  • Manifest reconciledFerryPass reconciliation not received for this sailing
  • No blocking restrictions recordedEngine load restriction in force, non-blocking
Authorised by
S. Khan, Harbour Master
Time
10:04
Inspections & certification
RequirementLast completedNext due / expiryStatus
Pre-departure inspection17 Aug 09:52Current voyageCurrent
Six-month safety systems inspection04 Apr04 OctCurrent
Life-saving equipment inspection27 May27 NovCurrent
Vessel certificate11 Feb 2027Current
Outstanding compliance issues
  • Cooling system inspection required on arrival, engine restriction in forceACT-0092

Crew and safety equipment: compliant.

Maintenance & condition

Condition by vessel domain, from maintenance reports, inspections, defect reports and completed repairs

Warning
DomainStatusOpenLatest significant issue
PropulsionWarning1Differential pressure high, load restriction applied
SteeringNormal0
ElectricalNormal0
Hull & StructureNormal0
Fire & Safety SystemsNormal0
Navigation & CommunicationsNormal0
Pumps & BilgeNormal0
Deck & Loading EquipmentNormal0
Auxiliary SystemsWarning1Coolant temperature above threshold
Maintenance records
Propulsion
Warning
  • MR-0246 Port fuel filter assembly, Differential pressure high, load restriction appliedRestricted to 55% port load

    High differential pressure across the port fuel filter assembly. Engine load restricted pending element renewal; replacement elements on order.

    Source: Defect report (DEF-1183)17 AugResponsible: Marine Engineering
Open maintenance section →

Open issues & actions

Significant current matters for this vessel

Full registers →
  • Risk RSK-011: Repeated crew procedure non-complianceEscalated

    3 recorded omissions in 30 days across two vessels.

    Open RSK-011
  • Risk RSK-016: Wet-weather slips on passenger stairsUnder review

    3 wet-deck slips recorded this quarter, all on stair access in rain.

    Open RSK-016
  • Risk RSK-017: Certificate expiring within 30 days, MV SabantoMonitoring

    Passenger ship safety certificate expires in 26 days; renewal survey not yet booked.

    Open RSK-017